Hotline: 021-69780975   Technical Department: +86 13916843608   Sales Department: +86 18616838565   After sales: 13585786639 简体中文
  1. Home | Technical Support | Conveyor Belt Installation Elongation and Tensioning Calculation

Technical Support

Conveyor Belt Installation Elongation and Tensioning Calculation

Installation Elongation / Tensioning (Conveyor Belt Installation Elongation and Tension Calculation)

2025-04-02
Installation Elongation / Tensioning (Conveyor Belt Installation Elongation and Tension Calculation)

All endless belts must be tensioned according to the calculated value / empirical range after being fitted on the machine and before formal use, to ensure the necessary

pull is achieved. In theory, after being tensioned to the standard, a belt will not elongate further in use.

Effective pull (N) = dynamic belt strength (N/mm belt width) × installation elongation

For example: for an 800 mm wide belt of a type rated at 10 N, at an elongation of 0.5%, the effective pull is
                          

  800 × 10 × 0.5% = 40 N

1. If the elongation is too small, the rated power required for belt conveying and transmission cannot be reached, and slipping may occur.

2. If the elongation is too large, the effective pull produced by the belt may cause the shaft to bend or even be damaged, and it also affects the service life of the belt.